EA2-B0-24-650-32A-DB [Carling Technologies]

Magnetic Circuit Breaker,;
EA2-B0-24-650-32A-DB
型号: EA2-B0-24-650-32A-DB
厂家: Carling Technologies    Carling Technologies
描述:

Magnetic Circuit Breaker,

电路保护
文件: 总13页 (文件大小:1948K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
E
E-Se  
-Series  
rie  
s
CIRCUIT BREAKER  
The E-Series hydraulic-magnetic circuit breaker is ideally suited for higher current and voltage applications. It is  
UL listed and CSA certified for branch circuit protection, which does not require a fuse back up. It is also UL  
recognized and CSA certified as a supplementary protector and as a manual motor controller.  
Its physical features include front and back mounting, screw and stud terminals and heavy duty box wire  
connectors for solid wire or a pressure plate connector for standard wire. The E-series is available with handle  
actuators and can be configured as .1-125 amps, up to 600VAC or 125VDC, with choice of time delays, actuator  
colors and 1 to 6 poles configuration. Additionally, a Power Selector device is also available.  
Resources:  
Configure a Complete Part  
Download CAD & Sales Drawing  
Product Highlights:  
•ꢀ ULꢀlistedꢀandꢀCSAꢀcertified  
•ꢀ Certifiedꢀforꢀcircuitꢀbranchꢀprotection  
•ꢀ Recognizedꢀasꢀaꢀsupplementaryꢀprotector  
ꢀ andꢀasꢀaꢀmanualꢀmotorꢀcontroller  
Typical Applications:  
•ꢀ HighꢀVoltageꢀ/ꢀHighꢀCurrentꢀApplications  
•ꢀ RenewableꢀEnergy  
•ꢀ Military  
•ꢀ IndustrialꢀControls  
•ꢀ Generators  
•ꢀ Optionalꢀpowerꢀselectorꢀdevice  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Email: sales@carlingtech.com  
Application Support: team2@carlingtech.com  
Phone: 860.793.9281 Fax: 860.793.9231  
www.carlingtech.com  
|
2
E-Series Circuit Breaker – General Specifications  
Electrical  
Mechanical  
Maximum Voltage  
600VAC 50/60 Hz, 125VDC (See  
Table A)  
Standard current coils: 0.100,  
0.250, 0.500, 1.00, 2.50, 5.00,  
7.50, 10.0, 15.0, 20.0, 25.0, 30.0,  
50.0, 60.0, 70.0 & 100 Amp.  
Endurance  
10,000 ON-OFF operations @ 6  
per minute; with rated Current and  
Voltage.  
All E-Series Circuit Breakers will  
trip on overload, even when  
Handle is forcibly held in the ON  
position.  
The operating Handle moves  
positively to the OFF position  
when an overload causes the  
breaker to trip.  
Current Ratings  
Trip Free  
Auxiliary Switch Rating SPDT; 10.1A 250VAC, 1.0A  
65VDC; 0.5A 80VDC, 0.1A 125VAC  
(with gold contacts).  
Trip Indication  
Insulation Resistance  
Minimum of 100 Megohms at 500  
VDC.  
Dielectric Strength  
UL, CSA: 2200 V 50/60 Hz for one  
minute between all electrically  
isolated terminals. E-Series Circuit  
Breakers comply with the 8mm  
spacing and 3750V 50/60 Hz  
dielectric requirements from  
hazardous voltage to operator  
accessible surfaces, between  
adjacent poles and from main  
circuits to auxiliary circuits per  
Publications EN 60950 and VDE  
0805.  
Physical  
Number of Poles  
Mounting  
1 - 6  
A 3” minimum spacing must be  
provided between the circuit  
breaker arc venting area on back  
connected E-Series circuit  
breakers and grounded  
obstructions. E-Series circuit  
breakers must be mounted on a  
vertical surface.  
Connectors, Box Type Front connected E-Series circuit  
breakers are supplied with box  
type pressure connectors that  
Resistance, Impedance Values from Line to Load Terminal  
- based on Series Trip Circuit  
Breaker.  
accept copper or aluminum  
conductors as follows: 1/0-14  
Copper, 1/0-12 Aluminum.  
Internal Circuit  
Configuration  
Series and Switch Only, (with or  
without auxiliary switch). Shunt  
with current coils.  
CURRENT  
(AMPS)  
TOLERANCE  
(%)  
0.10 - 5.0  
5.1 - 20.0  
20.1 - 50.0  
15  
25  
35  
Weight  
Approximately 252 grams/pole  
(Approximately 9 ounces/pole)  
Housing-Black; Actuator - See  
Ordering Scheme.  
Standard Colors  
Environmental  
Designed in accordance with requirements of specification  
MIL PRF-55629 & MIL-STD-202G as follows:  
Shock  
Withstands 100 Gs, 6ms, sawtooth  
while carrying rated current per  
Method 213, Test Condition “I”.  
Withstands 0.060” excursion from  
10-55 Hz, and 10 Gs 55-500 Hz, at  
rated current per Method 204C,  
Test Condition A.  
Pulse Tolerance Curves  
Vibration  
Time Delay Curves  
62, 64 & 66  
(100 Amps Max.)  
Time Delay Curves  
22, 24 & 26 (100 Amps Max.)  
Moisture Resistance  
Method 106D, i.e., ten 24-hour  
cycles @ + 25°C to +65°C, 80-98%  
RH.  
Salt Spray  
Method 101, Condition A (90-95%  
RH @ 5% NaCl Solution, 96 hrs).  
Method 107D, Condition A (Five  
cycles @ -55°C to +25°C to +85°C  
to +25°C).  
Thermal Shock  
Operating Temperature -40° C to +85° C  
*Manufacturer reserves the right to change product specification without prior notice.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
3
E-Series Circuit Breaker – General Specifications  
Electrical Tables  
Table A: Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case  
Circuit Breaker.  
E SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS  
VOLTAGE  
INTERRUPTING  
CAPACITY (AMPS)  
CURRENT RATING  
FULL LOAD AMPS  
HIGH  
INTERRUPTING  
CAPACITY  
(AMPS)  
CIRCUIT  
CONFIGURATION  
MAX.  
RATING  
FREQUENCY  
PHASE  
WITHOUT BACKUP  
FUSE  
80  
125  
DC  
---  
---  
---  
1
0.10 - 100  
0.10 - 100  
0.10 - 125  
0.10 - 125  
0.10 - 30  
31 - 100  
5,000  
5,000  
10,000  
10,000  
5,000  
5,000  
5,000  
5,000  
10,000  
5,000  
50,000  
10,000  
---  
DC  
125  
DC  
120  
50 / 60  
50 / 60  
50 / 60  
50 / 60  
50 / 60  
50 / 60  
50 / 60  
---  
SERIES  
240  
1
10,000  
240  
1
120 / 240  
120 / 240  
120 / 240  
240  
1
0.10 - 30  
31 - 100  
10,000  
---  
1
1
101 - 125  
0.10 - 100  
---  
3
---  
Table B: Lists UL Recognized & CSA Accepted configurations & performance capabilities as a Component Supplementary  
Protector.  
E -SERIES TABLE B: COMPONENT SUPPLEMENTARY PROTECTORS  
VOLTAGE  
CURRENT RATING  
SHORT CIRCUIT CAPACITY (AMPS)  
UL/CSA  
APPLICATION CODES  
CIRCUIT  
CONFIGURATION  
MAX.  
RATING  
FULL LOAD  
AMPS  
GENERAL  
PURPOSE AMPS  
FREQUENCY  
PHASE  
UL  
CSA  
WITH BACKUP  
FUSE3  
WITHOUT  
BACKUP FUSE  
125  
125  
DC  
DC  
---  
---  
---  
---  
---  
1
0.02 - 100  
---  
---  
101 - 120  
0.02 - 125  
---  
---  
---  
5,000  
5,000  
5,000  
5,000  
5,000  
5,000  
5,000  
---  
TC1,2, OL1, U1 TC1,2, OL1, U1  
TC1,2, OL0, U1 TC1,2, OL0, U1  
TC1, OL0, U3 TC1, OL0, U3  
TC1,2, OL1, U1 TC1,2, OL1, U1  
TC1,2, OL1, U1 TC1,2, OL1, U1  
TC1,2, OL0, U1 TC1,2, OL0, U1  
TC1,2, OL1, U1 TC1,2, OL1, U1  
TC1,2, OL1, C1 TC1,2, OL1, C1  
TC1,2, OL1, U1 TC1,2, OL1, U1  
TC1,2, OL1, C1 TC1,2, OL1, C1  
TC1,2, OL1, C1 TC1,2, OL1, C1  
TC1,2, OL1, C1 TC1,2, OL1, C1  
TC1,2, OL1, C1 TC1,2, OL1, C1  
TC1, OL0, U3 TC1, OL0, U3  
150  
DC  
---  
---  
160  
DC  
0.02 - 100  
0.02 - 100  
---  
---  
150 / 300  
120 / 240  
240  
DC  
---  
---  
SERIES &  
SHUNT  
50 / 60  
50 / 60  
50 / 60  
0.02 - 100  
---  
---  
1
0.02 - 100  
0.02 - 100  
---  
250  
1
---  
10,000  
---  
5,000  
---  
277  
50 / 60  
1
0.02 - 100  
---  
10,000  
10,000  
10,000  
10,000  
---  
480  
50 / 60  
50 / 60  
50 / 60  
DC  
1 & 3  
1 & 3  
1 & 3  
---  
0.02 - 100  
0.02 - 50  
0.02 - 100  
---  
---  
---  
---  
480 1  
600  
---  
---  
---  
600 2  
125  
160  
240  
277  
480  
600  
0.02 - 125  
5,000  
DC  
---  
0.02 - 120  
0.02 - 100  
0.02 - 100  
0.02 - 100  
0.02 - 100  
0.02 - 100  
DC  
---  
SWITCH  
ONLY  
50 / 60  
50 / 60  
50 / 60  
50 / 60  
1
1
1 & 3  
1 & 3  
Notes:  
1
2
3
Per pole opposite polarity rating - Delta Configuration.  
4 Poles connected in series  
Requires branch circuit backup with a UL Listed Type K5 or RK5 fuse rated 15A minimum  
and no more than 4 times full load amp rating and not to exceed 225A.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
4
E-Series Circuit Breaker – General Specifications  
Electrical Tables  
Table C: Lists UL Recognized, CSA Accepted and VDE Certified configurations and performance capabilities as a  
Component Supplementary Protector.  
E -SERIES TABLE C: COMPONENT SUPPLEMENTARY PROTECTORS WITH VDE  
VOLTAGE  
CURRENT RATING  
SHORT CIRCUIT CAPACITY (AMPS)  
UL/CSA VDE (Icn)  
APPLICATION CODES  
CIRCUIT  
CONFIGURATION  
MAX.  
RATING  
CONSTRUCTION NOTES  
WITHOUT  
BACKUP  
FUSE  
WITHOUT  
BACKUP  
FUSE  
FREQUENCY PHASE FULL LOAD AMPS  
UL  
CSA  
WITH BACKUP  
FUSE1  
125  
240  
DC  
---  
0.1 - 100  
0.1 - 100  
---  
5,000  
5,000  
TC1,2, OL1, U1 TC1,2, OL1, U1  
1 or 2 Poles  
1 - 5 Poles. Up to 4  
SERIES &  
SHUNT  
50 / 60  
1 & 3  
---  
5,000  
5,000  
TC1,2, OL1, U1 TC1,2, OL1, U1 Current Poles, 1 Voltage  
Pole  
2 - 5 Poles. Up to 4  
TC1,2, OL1, C1 TC1,2, OL1, C1 Current Poles, 1 Voltage  
Pole  
415  
50 / 60  
1 & 3  
0.1 - 100  
10,000  
---  
4,000  
---  
125  
240  
415  
DC  
0.1 - 125  
0.1 - 100  
0.1 - 100  
SWITCH ONLY  
50 / 60  
50 / 60  
1 & 3  
1 & 3  
Notes:  
1
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum  
and no more than 4 times full load amp rating and not to exceed 225 amps.  
Table D: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for  
Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft  
Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors.  
E SERIES TABLE D : UL1500 (Marine Ignition Protection)  
VOLTAGE  
SHORT CIRCUIT  
CAPACITY (AMPS)  
CURRENT RATING  
FULL LOAD AMPS  
APPLICATION CODES  
CIRCUIT  
CONFIGURATION  
MAX.  
RATING  
FREQUENCY  
PHASE  
WITHOUT BACKUP  
FUSE  
UL  
CSA  
65  
DC  
---  
1
0.02 - 100  
0.02 - 100  
0.02 - 100  
5,000  
1,500  
1,500  
TC1,2,OL1,U1 TC1,2,OL1,U1  
TC1,2,OL1,U1 TC1,2,OL1,U1  
TC1,2,OL1,U1 TC1,2,OL1,U1  
SERIES  
125  
250  
50 / 60  
50 / 60  
1
Agency Certifications  
Component Supplementary  
Protector (Class 3215 30, File  
047848 0 000)  
UL Recognized  
UL Standard 1077  
CSA Accepted  
Component Recognition Program  
as Protectors, Supplementary  
(Guide QVNU2, File E75596)  
CSA Standard C22.2 No. 235  
Component Recognition Program  
as Manual Motor Controls (Guide  
NLRV2, File E135367)  
Circuit Breaker Molded Case  
(Class 1432 01, File 093910),  
CSA Standard C22.2 No. 5.1 - M  
CSA Certified  
TUV Certified  
VDE Certified  
Protectors, Supplementary for  
Marine Electrical & Fuel Systems  
(Guide PEQZ2, File E75596)  
Ignition Protection  
EN60934 under License No.  
R72031056  
UL Standard 1500  
EN60934, VDE 0642 under File  
No. 10537  
UL Listed  
UL Standard 489  
Circuit Breakers, Molded Case  
(Guide DIVQ, File E129899)  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
5
E-Series Circuit Breaker - UL 1077 – Ordering Scheme  
E A 2 B 0 24 450 1 2 A C B  
8
9
10  
Mounting/  
Barriers  
11  
12  
Agency  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color  
Maximum  
Series  
Actuator  
Poles  
Circuit  
Auxiliary  
Switch  
Frequency  
& Delay  
Current Rating  
Application Approval  
Rating  
12  
8 TERMINAL  
1 SERIES  
BACK CONNECTED (FRONT MOUNTED ONLY)  
MAX. RATING  
E
9
9
9
1
10-32 Stud (All Terminals)  
1/4-20 Stud (All Terminals)  
M5 Stud (Line & Load)  
M6 Stud (Line & Load)  
50 A  
120 A  
50 A  
2
A
B
2 ACTUATOR  
9
100 A  
A
Handle, one per pole  
FRONT CONNECTED (BACK MOUNTED ONLY)  
MAX. RATING  
10  
1
3
Box Wire Connector (Line & Load)  
100 A  
3 POLES  
11  
C
4
Box Wire Connector with Pressure Plate (Line & Load)  
10-32 Screw (Line & Load)  
100 A  
50 A  
50 A  
50 A  
50 A  
1
One  
Two  
3
4
Three  
Four  
5
6
Five  
Six  
2
D
5
M5 Screw (Line & Load)  
10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load)  
M5 “Bus-Type” Screw (Line), 10-32 Screw (Load)  
2
E
6
F
4 CIRCUIT  
10  
11  
3
10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A  
10-32 “Bus-Type” Screw (Line), Box Wire Connector  
(
)
(
)
A
B
C
D
Switch Only no coil  
E
F
G
Shunt Trip voltage  
(
)
(
)
Series Trip current  
Relay Trip current  
with Pressure Plate (Load)  
100 A  
100 A  
100 A  
100 A  
100 A  
(
)
(
)
Series Trip voltage  
Relay Trip voltage  
7
1/4-20 Screw (Line & Load)  
(
)
Shunt Trip current  
G
8
M6 Screw (Line & Load)  
1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load)  
M6 “Bus-Type” Screw (Line), M6 Screw (Load)  
4
H
9
5 AUXILIARY SWITCH  
10  
11  
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A  
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector  
0
2
3
4
without Auxiliary Switch  
6
7
S.P.S.T. 0.110 Q.C. Terminals  
S.P.S.T. 0.110 Q.C. Terminals  
(Gold Contacts)  
S.P.S.T. 0.187 Q.C. Terminals  
S.P.D.T. 0.187 Q.C. Terminals  
J
S.P.D.T. 0.110 Q.C. Terminals  
S.P.D.T. 0.139 Solder Lug  
S.P.D.T. 0.110 Q.C. Terminals  
(Gold Contacts)  
with Pressure Plate (Load)  
100 A  
8
9
13  
9 ACTUATOR COLOR & LEGEND  
Actuator Color  
White  
Black  
Red  
Green  
Blue  
Yellow  
Gray  
Orange  
I-O  
A
C
F
H
K
M
P
ON-OFF  
Dual  
Legend Color  
Black  
White  
White  
White  
White  
Black  
Black  
Black  
6 FREQUENCY & DELAY  
B
D
G
J
1
2
3
4
5
6
7
8
3
03 DC 50/60Hz, Switch Only  
34 DC, 50/60Hz Medium  
36 DC, 50/60Hz Long  
5
10 DC Instantaneous  
12 DC Short  
14 DC Medium  
16 DC Long  
62 50/60Hz Short, High-inrush  
64 50/60Hz Medium, High-inrush  
66 50/60Hz Long, High-inrush  
72 DC, Short,High-inrush  
74 DC,Medium, High-inrush  
76 DC, Long, High-inrush  
L
5
N
Q
S
20 50/60Hz Instantaneous  
22 50/60Hz Short  
24 50/60Hz Medium  
26 50/60Hz Long  
R
6
6
6
92 DC, 50/60Hz Short, High-inrush  
30 DC, 50/60Hz Instantaneous  
32 DC, 50/60Hz Short  
94 DC, 50/60Hz Medium, High-inrush  
96 DC, 50/60Hz Long, High-inrush  
10 MOUNTING / BARRIERS  
BACK CONNECTED (FRONT MOUNTED ONLY)  
Mounting Inserts  
7
7 CURRENT RATING (AMPERES)  
CODE AMPERES  
A
B
6-32  
ISO M3  
020 0.020  
025 0.025  
030 0.030  
035 0.035  
040 0.040  
045 0.045  
050 0.050  
055 0.055  
060 0.060  
065 0.065  
070 0.070  
075 0.075  
080 0.080  
085 0.085  
090 0.090  
090 0.095  
210 0.100  
215 0.150  
220 0.200  
225 0.250  
230 0.300  
235 0.350  
240 0.400  
245 0.450  
250 0.500  
255 0.550  
260 0.600  
265 0.650  
270 0.700  
275 0.750  
280 0.800  
285 0.850  
290 0.900  
295 0.950  
410 1.000  
512 1.250  
415 1.500  
517 1.750  
420 2.000  
522 2.250  
425 2.500  
527 2.750  
430 3.000  
435 3.500  
440 4.000  
445 4.500  
450 5.000  
455 5.500  
460 6.000  
465 6.500  
470 7.000  
475 7.500  
480 8.000  
485 8.500  
490 9.000  
495 9.500  
610 10.000  
710 10.500  
611 11.000  
711 11.500  
612 12.000  
712 12.500  
613 13.000  
614 14.000  
615 15.000  
616 16.000  
617 17.000  
618 18.000  
620 20.000  
622 22.000  
624 24.000  
625 25.000  
630 30.000  
635 35.000  
640 40.000  
650 50.000  
660 60.000  
670 70.000  
680 80.000  
690 90.000  
810 100.000  
811 110.000  
812 120.000  
14  
FRONT CONNECTED (BACK MOUNTED ONLY)  
Back Mounting Foot Type Front Mounting Inserts (Optional Use)  
C
D
E
F
Short  
Short  
Long  
Long  
6-32  
ISO M3  
6-32  
ISO M3  
15  
11 MAXIMUM APPLICATION RATING  
16  
16  
16  
16  
A
B
C
D
E
F
65 VDC, 120 A  
G
H
J
L
T
600 VAC, 100 A  
125 VDC, 120 A  
120/240 VAC, 100 A  
240 VAC, 100 A  
277/480 VAC, 100 A  
277 VAC, 100 A  
480 VAC, 100 A  
415 VAC, 100 A  
160 VDC, 100 A  
16  
125 VDC/240 VAC, 100 A  
125 VDC/415 VAC, 100 A  
16  
W
12 AGENCY APPROVAL  
B
D
UL 1077 / UL508 Recognized & CSA Accepted  
UL 1077 Recognized, CSA Accepted, & VDE Certified  
8
912 125.000  
5
OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS)  
4
5
Auxiliary Switch available on Switch Only and Series Trip units. On multi-pole units, only  
one auxiliary switch is normally supplied mounted in the extreme right pole. Back mounted  
units require special mounting provisions when auxiliary switch is specified. VDE approval  
on Auxilary Switch Codes 0,2,3 & 4 only.  
Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay  
Codes 10 & 20. Series Trip construction with a voltage coil s VDE approved only if tied to  
a protected pole.  
Frequency & Delay Codes 92,94 & 96 are not VDE Certified.  
Current Coil Ratings 0.100 - 100 ams are VDE Certified.  
A06 6 DC, 5 DC  
A12 12 DC, 10 DC  
A18 18 DC, 15 DC  
A24 24 DC, 20 DC  
A32 32 DC, 25 DC  
A48 48 DC, 40 DC  
A65 65 DC, 55 DC  
J48 48 AC, 40 AC  
B25 125 DC, 100 DC J65 65 AC, 55 AC  
J06 6 AC, 5 AC  
K20 120 AC, 65 AC  
L40 240 AC, 130 AC  
J12 12 AC, 10 AC  
J18 18 AC, 15 AC  
J24 24 AC, 20 AC  
6
7
8
9
125 A rating (Code 912) available as a Switch Only (Circuit Code A), rated 125 VDC (Code B).  
An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 (Terminal  
Code 1). 1/4-20 (Code 2), M5 (Code A), and M6 (Code B) terminals per UL requirement.  
Notes:  
1
VDE approval on 1-5 poles only. Standard multi-pole units identical poles except when  
specifying auxiliary switch - (see Note 4). For mixed ratings, consult factory.  
Switch Only & Series Trip construction available with either front or back connected  
terminals.  
Shunt construction available with back connected terminals, (Terminal Codes 1 & 2) only.  
Circuit Codes B,C & D are VDE approved.  
Switch Only construction: 30 amps or less select Current Rating Code 630; 31-70 amps,  
select Current Rating code 670; 71-100 amps, select Current Rating Code 810; 101-125  
amps Select Current Rating Code 912. Switch Only is VDE approved only if tied to a  
protected pole.  
10 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG.  
aluminum wire.  
11 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details.  
12 Terminal Codes A,B,D,E,G & H are not VDE Certified.  
2
13 VDE approvals require Dual (I-O, ON-OFF) or I-O markings on all handles.  
14 Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting  
inserts normally supplied. However, terminal connections must be made prior to mounting.  
15 Application ratings B,D,J,T & W are available with VDE.  
3
16 415, 480 & 600 VAC ratings require 3 or 4 pole break 3Ø and 2 pole break 1Ø.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
6
E-Series Circuit Breaker - UL 489 – Ordering Scheme  
24  
1 2 A  
E A 2 B 0  
C C  
Application Approval  
Rating  
450  
8
9
10  
Mounting/  
Barriers  
11  
Maximum  
12  
Agency  
6
1
2
3
4
5
7
Terminal  
Actuator  
Color  
Frequency  
& Delay  
Series  
Actuator  
Poles  
Circuit  
Auxiliary  
Switch  
Current Rating  
7
8 TERMINAL  
1 SERIES  
E
BACK CONNECTED (FRONT MOUNTED ONLY)  
MAX. RATING  
50 A  
8
8
1
2
10-32 Stud (All Terminals)  
1/4-20 Stud (All Terminals)  
125 A  
2 ACTUATOR  
FRONT CONNECTED (BACK MOUNTED ONLY)  
MAX. RATING  
A
Handle, one per pole  
9
10  
3
C
4
5
6
F
Box Wire Connector (Line & Load)  
100 A  
Box Wire Connector with Pressure Plate (Line & Load)  
10-32 Screw (Line & Load)  
100 A  
50 A  
50 A  
1
3 POLES  
10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load)  
1
2
One  
Two  
3
4
Three  
Four  
5
6
Five  
Six  
9
10  
10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A  
10-32 “Bus-Type” Screw (Line), Box Wire Connector  
with Pressure Plate (Load)  
100 A  
125 A  
100 A  
2
7
8
9
J
1/4-20 Screw (Line & Load)  
4 CIRCUIT  
1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load)  
( )  
Series Trip current  
Series Trip voltage  
B
C
9
10  
3
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A  
1/4-20 “Bus-Type” Screw (Line), Box Wire Connector  
(
)
with Pressure Plate (Load)  
100 A  
4
5 AUXILIARY SWITCH  
0
2
3
4
without Auxiliary Switch  
6
7
S.P.S.T. 0.110 Q.C. Terminals  
S.P.S.T. 0.110 Q.C. Terminals  
(Gold Contacts)  
12  
9 ACTUATOR COLOR & LEGEND  
S.P.D.T. 0.110 Q.C. Terminals  
S.P.D.T. 0.139 Solder Lug  
S.P.D.T. 0.110 Q.C. Terminals  
(Gold Contacts)  
Actuator Color  
White  
Black  
Red  
Green  
Blue  
ON-OFF Dual  
Legend Color  
Black  
White  
White  
White  
White  
Black  
Black  
Black  
8
9
S.P.S.T. 0.187 Q.C. Terminals  
S.P.D.T. 0.187 Q.C. Terminals  
B
D
G
J
1
2
3
4
5
6
7
8
6 FREQUENCY & DELAY  
L
5
10  
12  
14  
16  
20  
22  
24  
26  
DC Instantaneous  
DC Short  
62 50/60Hz Short, High-inrush  
64 50/60Hz Medium, High-inrush  
66 50/60Hz Long, High-inrush  
72 DC, Short,High-inrush  
74 DC,Medium, High-inrush  
76 DC, Long, High-inrush  
Yellow  
Gray  
Orange  
N
Q
S
DC Medium  
DC Long  
5
50/60Hz Instantaneous  
50/60Hz Short  
50/60Hz Medium  
50/60Hz Long  
10 MOUNTING / BARRIERS  
BACK CONNECTED (FRONT MOUNTED ONLY)  
Mounting Inserts  
A
B
6-32  
7
ISO M3  
7 CURRENT RATING (AMPERES)  
CODE AMPERES  
11  
FRONT CONNECTED (BACK MOUNTED ONLY)  
020 0.020  
025 0.025  
030 0.030  
035 0.035  
040 0.040  
045 0.045  
050 0.050  
055 0.055  
060 0.060  
065 0.065  
070 0.070  
075 0.075  
080 0.080  
085 0.085  
090 0.090  
090 0.095  
210 0.100  
215 0.150  
220 0.200  
225 0.250  
230 0.300  
235 0.350  
240 0.400  
245 0.450  
250 0.500  
255 0.550  
260 0.600  
265 0.650  
270 0.700  
275 0.750  
280 0.800  
285 0.850  
290 0.900  
295 0.950  
410 1.000  
512 1.250  
415 1.500  
517 1.750  
420 2.000  
522 2.250  
425 2.500  
527 2.750  
430 3.000  
435 3.500  
440 4.000  
445 4.500  
450 5.000  
455 5.500  
460 6.000  
465 6.500  
470 7.000  
475 7.500  
480 8.000  
485 8.500  
490 9.000  
495 9.500  
610 10.000  
710 10.500  
611 11.000  
711 11.500  
612 12.000  
712 12.500  
613 13.000  
614 14.000  
615 15.000  
616 16.000  
617 17.000  
618 18.000  
620 20.000  
622 22.000  
624 24.000  
625 25.000  
630 30.000  
635 35.000  
640 40.000  
650 50.000  
660 60.000  
670 70.000  
680 80.000  
690 90.000  
810 100.000  
811 110.000  
812 120.000  
Back Mounting Foot Type Front Mounting Inserts (Optional Use)  
C
D
E
F
Short  
Short  
Long  
Long  
6-32  
ISO M3  
6-32  
ISO M3  
11 MAXIMUM APPLICATION RATING  
1
120 VAC  
B
C
D
125 VDC  
13  
120/240 VAC, 100 A  
240 VAC, 100 A  
12 AGENCY APPROVAL  
C
F
UL 489 Listed & CSA Certified  
UL 489 Listed, CSA Certified, & VDE Certified  
8
Notes:  
912 125.000  
1
Standard multi-pole units identical poles except when specifying auxiliary switch -  
(see Note 4). For mixed ratings, consult factory. VDE Certification on 1-5 poles only.  
Series Trip construction available with either front or back connected terminals.  
Series Trip construction with a voltage coil is not available as a single pole unit and must be  
tied to a protected pole.  
On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme  
right pole per Figure A. Back mounted units require special mounting provisions when  
auxiliary switch is specified. VDE Certification on auxilary switch codes 0, 2, 3 & 4 only.  
Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay  
Codes 10 & 20.  
5
OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS)  
2
3
A06 6 DC, 5 DC  
A12 12 DC, 10 DC  
A18 18 DC, 15 DC  
A24 24 DC, 20 DC  
A32 32 DC, 25 DC  
A48 48 DC, 40 DC  
A65 65 DC, 55 DC  
J48 48 AC, 40 AC  
B25 125 DC, 100 DC J65 65 AC, 55 AC  
J06 6 AC, 5 AC  
K20 120 AC, 65 AC  
L40 240 AC, 130 AC  
4
J12 12 AC, 10 AC  
J18 18 AC, 15 AC  
J24 24 AC, 20 AC  
5
6
7
8
Frequency & Delay Codes 92, 94 & 96 are not VDE Certified.  
Current Ratings under 0.100 amps are not VDE Certified .  
An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 Stud  
(Terminal Code 1) or 1/4-20 Stud (Code 2) terminals per UL requirement.  
Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG.  
aluminum wire.  
9
10 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details.  
11 Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting  
inserts normally supplied. However, terminal connections must be made prior to mounting.  
12 VDE Certification requires dual (I-O , ON-OFF) markings on all handles.  
13 Not available with VDE Certification.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
7
E-Series Circuit Breaker – Circuit & Terminal Diagrams  
Circuit & Terminal Diagrams: in. [mm]  
Notes:  
1
2
3
4
All dimensions are in inches [millimeters].  
Tolerance ±.020 [.51] unless otherwise specified.  
0-50 amps: 10-32 & M5 Studs .625±.062/15.88±1.574 long.  
51-120 amps: 1/4-20 & M6 Studs .750±.062/19.05±1.574 long.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
8
E-Series Circuit Breaker – Dimensional Specifications  
Dimensional Specifications: in. [mm]  
Notes:  
1
2
1/4 -20 stud terminal in Series Trip circuit configuration shown.  
A 3” min spacing must be provided between the circuit breaker arc venting area  
of back connected E-Series circuit breaker and grounded obstructions.  
All dimensions are in inches [millimeters].  
3
4
5
Tolerance ±.020 [.51] unless otherwise specified.  
Circuit breakers must be mounted on vertical surface.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
9
E-Series Circuit Breaker – Dimensional Specifications  
Dimensional Specifications: in. [mm]  
Notes:  
1
2
3
4
All dimensions are in inches [millimeters].  
Tolerance ±.020 [.51] unless otherwise specified.  
Box wire connector terminal in Series Trip circuit configuration shown.  
Circuit breakers must be mounted on vertical surface.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
10  
Time Delay Values – E-Series Circuit Breaker  
NOTES  
Delay Curves 10,20,30: Breakers to hold 100% and must trip at 150% of rated current and greater wthin the time limit shown in these curves.  
Delay Curves 12,14,16,22,24,26,62,64,66,72,74,76: Breakers to hold 100% and must trip at 125% of rated current and greater wthin the time limit shown in these curves.  
Delay Curves 32,34,36,92,94,96: Breakers to hold 100% and must trip at 135% of rated current and greater wthin the time limit shown in these curves.  
All curves: Data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading: Breakers are mounted in standard wall-mount position.  
The minimum inrush pulse tolerance handling capacity on the above standard delays is 16 times rated current &20 times rated current for high inrush delays based on a 60Hz 1/2 cycle, 8.33 ms pulse.  
AC  
DC  
Instantaneous  
PERCENT OF RATED CURRENT  
PERCENT OF RATED CURRENT  
Short  
PERCENT OF RATED CURRENT  
PERCENT OF RATED CURRENT  
Medium  
PERCENT OF RATED CURRENT  
PERCENT OF RATED CURRENT  
Long  
PERCENT OF RATED CURRENT  
PERCENT OF RATED CURRENT  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
11  
Time Delay Values – E-Series Circuit Breaker  
AC/DC  
Instantaneous  
PERCENT OF RATED CURRENT  
Short  
PERCENT OF RATED CURRENT  
Medium  
PERCENT OF RATED CURRENT  
Long  
PERCENT OF RATED CURRENT  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
12  
Sales Representatives, Distributors & Company Profile  
Authorized Sales Representatives and Distributors  
Click on a region of the map below to find your local representatives and distributors or visit  
www.carlingtech.com/findarep.  
CANADA  
EUROPE  
USA  
MIDDLE  
EAST  
MEXICO  
AFRICA  
ASIA-PACIFIC  
OCEANIA  
SOUTH  
AMERICA  
About Carling  
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches  
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power  
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,  
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical  
components, they engineer powerful solutions! To learn more about Carling please visit  
www.carlingtech.com/company-profile.  
To view all of Carling’s environmental, quality, health & safety certifications please visit  
www.carlingtech.com/environmental-certifications  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
Worldwide Headquarters  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Phone: 860.793.9281 Fax: 860.793.9231  
@
Email: sales carlingtech.com  
@
Northern Region Sales Office: nrsm carlingtech.com  
@
Southeast Region Sales Office: sersm carlingtech.com  
@
Midwest Region Sales Office: mrsm carlingtech.com  
@
West Region Sales Office: wrsm carlingtech.com  
@
Latin America Sales Office: larsm carlingtech.com  
Asia-Pacific Headquarters  
Carling Technologies, Asia-Pacific Ltd.,  
Suite 1607, 16/F Tower 2, The Gateway,  
Harbour City, 25 Canton Road,  
Tsimshatsui, Kowloon, Hong Kong  
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332  
@
Email: sales carlingtech.com.hk  
@
Shenzhen, China: shenzhen carlingtech.com  
@
Shanghai, China: shanghai carlingtech.com  
@
Pune, India: india carlingtech.com  
@
Kaohsiung, Taiwan: taiwan carlingtech.com  
@
Yokohama, Japan: japan carlingtech.com  
|
|
Europe Middle East Africa Headquarters  
Carling Technologies LTD  
4 Airport Business Park, Exeter Airport,  
Clyst Honiton, Exeter, Devon, EX5 2UL, UK  
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477  
@
Email: ltd.sales carlingtech.com  
@
Germany: gmbh carlingtech.com  
@
France: sas carlingtech.com  
www.carlingtech.com  
REV_01_2019  

相关型号:

EA2-B0-24-670-73C-CC

Magnetic Circuit Breaker,
Carling Techn

EA2-B0-26-450-32E-HB

Magnetic Circuit Breaker,
Carling Techn

EA2-B0-26-475-32F-FB

Magnetic Circuit Breaker,
Carling Techn

EA2-B0-26-610-1DA-EB

Magnetic Circuit Breaker,
Carling Techn

EA2-B0-26-615-22A-DF

Magnetic Circuit Breaker,
Carling Techn

EA2-B0-26-625-22A-DF

Magnetic Circuit Breaker,
Carling Techn

EA2-B0-26-670-32E-GB

Magnetic Circuit Breaker,
Carling Techn

EA2-B0-26-810-32E-HB

Magnetic Circuit Breaker,
Carling Techn

EA2-B0-64-670-22A-CC

Magnetic Circuit Breaker,
Carling Techn

EA2-B0-64-680-2DA-CC

Magnetic Circuit Breaker,
Carling Techn

EA2-B0-76-670-22A-AB

Magnetic Circuit Breaker,
Carling Techn

EA2-B2-16-460-12A-BC

Magnetic Circuit Breaker,
Carling Techn